Three axis microstepping drive and power supply board
This high performance micro-stepper drive card was designed to complement our low cost AMC-E stepper, standalone machine control card. It can be neatly
mounted either above, below, or beside the AMC-E stepper machine
control card and connected to it via one ribbon and one 3 pin power cable.
The drive card incorporates 3 axes of motor drives, machine safety circuits, power supplies for both
the AMC-E and the stepper drives, and status indicators.
Connections to your machine are made via plug in screw terminal connectors.
Intended applications for the 3 axis stepper driver include: engraving machines, routing machines, milling machines,
lathes, and dispensing machines.
Due to its capability of operating at high voltages and of supporting selectable high micro-stepping
resolutions, the drive is capable of running your machine very rapidly, smoothly and quietly, and overcomes
many of the resonance problems that occur when using coarser step resolutions.
Specification
| Parameter |
Description |
DC Power
Motor Supply
Logic and output Supply Fuses
FS1 (Logic Supply)
FS2 (Bus Supply)
FS3,4,5 (Motor Phases) |
12V to 55V DC (60V absolute maximum)
24VDC +/- 15%
T2AL 250V (5 x 20mm)
T5AL 250V (5 x 20mm)
T3.15AL 250V (5 x 20mm) |
Power Supplies
24V
24VI switched via safety circuit |
Provides power for AMC-E stepper motion control card
Provides power to drive AMC-E stepper outputs |
| Status indicators |
LED's indicate status of:
Motor bus supply
+24V supply
+24VI supply
+5v logic supply
Status of FS1, 2 and 3
Status of safety loops 1 and 2 |
| Cooling |
Integral fan cools high power dissipation components |
Amplifiers
Number of Controllable Axes
Type
Motor Resolution
Protection
Short Circuit
Thermal Shutdown
Continuous Output Current
Peak Output Current
Maximum Stepping
Rate
Micro-Step Resolution
Nominal Chopping Frequency |
3
Bipolar Chopper
200 steps/revolution
Phase to phase and across phases
175oC
Independently adjustable 0.3A to 3.0A per phase
6A for 1500mS
1MHz
4 options, typically 10, 20,
36, or 50 (factory configured)
20KHz |
Command Interface
Step Inputs
Direction Inputs
Drive Enable Inputs |
3
3
1 |
| Connectors |
Plug in screw terminal blocks ease installation & maintainance |
| Sefety Circuit |
Dual channel providing 24VDC to customer supplied power-switching contactors which can be used to lock guards
Supports remote customer supplied [Drive Power On] switch